634852
SMARTer® Ultra® Low Input RNA Kit for Sequencing - v3
192 Rxns
Inquire for Quotation
*
The SMARTer Ultra Low Input RNA Kit for Sequencing - v3 allows direct synthesis of high-quality cDNA when starting with 1–1,000 cells or 10 pg–10 ng of total RNA. The kit has been designed and validated to prepare cDNA samples for library preparation and sequencing using the Ion Torrent or Illumina sequencing platforms. SMART (S witching M echanism A t 5' End of R NA T emplate) technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit improves on previous generations of SMARTer Ultra Low kits by simplifying the workflow, identifying more genes, and increasing the representation of GC-rich genes. It is a complete kit that supplies all required reagents, including SeqAmp DNA polymerase, an optimized PCR enzyme that has been verified to perform well with this kit.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634850
SMARTer® Ultra® Low Input RNA Kit for Sequencing - v3
48 Rxns
USD $4802.00
The SMARTer Ultra Low Input RNA Kit for Sequencing - v3 allows direct synthesis of high-quality cDNA when starting with 1–1,000 cells or 10 pg–10 ng of total RNA. The kit has been designed and validated to prepare cDNA samples for library preparation and sequencing using the Ion Torrent or Illumina sequencing platforms. SMART (S witching M echanism A t 5' End of R NA T emplate) technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit improves on previous generations of SMARTer Ultra Low kits by simplifying the workflow, identifying more genes, and increasing the representation of GC-rich genes. It is a complete kit that supplies all required reagents, including SeqAmp DNA polymerase, an optimized PCR enzyme that has been verified to perform well with this kit.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634848
SMARTer® Ultra® Low Input RNA Kit for Sequencing - v3
12 Rxns
USD $1714.00
The SMARTer Ultra Low Input RNA Kit for Sequencing - v3 allows direct synthesis of high-quality cDNA when starting with 1–1,000 cells or 10 pg–10 ng of total RNA. The kit has been designed and validated to prepare cDNA samples for library preparation and sequencing using the Ion Torrent or Illumina sequencing platforms. SMART (S witching M echanism A t 5' End of R NA T emplate) technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit improves on previous generations of SMARTer Ultra Low kits by simplifying the workflow, identifying more genes, and increasing the representation of GC-rich genes. It is a complete kit that supplies all required reagents, including SeqAmp DNA polymerase, an optimized PCR enzyme that has been verified to perform well with this kit.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634828
SMARTer® Ultra® Low Input RNA for Illumina® Sequencing - HV
96 Rxns
USD $8601.00
SMARTer Ultra Low Input RNA for Illumina Sequencing - HV allows high-quality cDNA synthesis when starting with very low input amounts of total RNA. The kit is regularly tested with 100 pg of total RNA, and has been shown to perform robust cDNA synthesis with RNA from a single cell (10 pg equivalent). It includes the Advantage 2 PCR Kit for PCR amplification and validation. The kit has been designed and validated to prepare cDNA samples for sequencing and quantitation with the Illumina HiSeq, MiSeq, and Genome Analyzer sequencing instruments. SMART technology offers unparalleled sensitivity and unbiased amplification of cDNA transcripts, enabling a direct start from your sample. Most importantly, SMART technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit accommodates an input volume of up to 9 μl.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634823
SMARTer® Ultra® Low Input RNA for Illumina® Sequencing - HV
24 Rxns
USD $3550.00
SMARTer Ultra Low Input RNA for Illumina Sequencing - HV allows high-quality cDNA synthesis when starting with very low input amounts of total RNA. The kit is regularly tested with 100 pg of total RNA, and has been shown to perform robust cDNA synthesis with RNA from a single cell (10 pg equivalent). It includes the Advantage 2 PCR Kit for PCR amplification and validation. The kit has been designed and validated to prepare cDNA samples for sequencing and quantitation with the Illumina HiSeq, MiSeq, and Genome Analyzer sequencing instruments. SMART technology offers unparalleled sensitivity and unbiased amplification of cDNA transcripts, enabling a direct start from your sample. Most importantly, SMART technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit accommodates an input volume of up to 9 μl.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634820
SMARTer® Ultra® Low Input RNA for Illumina® Sequencing - HV
12 Rxns
USD $1895.00
SMARTer Ultra Low Input RNA for Illumina Sequencing - HV allows high-quality cDNA synthesis when starting with very low input amounts of total RNA. The kit is regularly tested with 100 pg of total RNA, and has been shown to perform robust cDNA synthesis with RNA from a single cell (10 pg equivalent). It includes the Advantage 2 PCR Kit for PCR amplification and validation. The kit has been designed and validated to prepare cDNA samples for sequencing and quantitation with the Illumina HiSeq, MiSeq, and Genome Analyzer sequencing instruments. SMART technology offers unparalleled sensitivity and unbiased amplification of cDNA transcripts, enabling a direct start from your sample. Most importantly, SMART technology enriches for full-length transcripts and maintains the true representation of the original mRNA transcripts; these factors are critical for transcriptome sequencing and gene expression analysis. This kit accommodates an input volume of up to 9 μl.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
635007
SMARTer® Stranded Total RNA-Seq Kit - Pico Input Mammalian
96 Rxns
USD $5330.00
The SMARTer Stranded Total RNA-Seq Kit - Pico Input Mammalian is used to generate strand-specific RNA-seq libraries for Illumina sequencing using purified total RNA input ranging from 250 pg–10 ng. This kit takes advantage of SMARTer Stranded RNA-seq technology, based on our proprietary SMART (S witching M echanism a t the 5' end of R NA T emplate) technology, with the added benefits of locked nucleic acid (LNA) technology as in the SMART-Seq v4 kit. The integrated post-cDNA synthesis removal of abundant molecules originating from rRNA makes the workflow extremely sensitive with excellent reproducibility and low mapping to rRNA. This method was developed to work with either high- or low-quality total RNA and does not require additional rRNA removal methods or kits. Final libraries retain strand of origin information.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
635006
SMARTer® Stranded Total RNA-Seq Kit - Pico Input Mammalian
48 Rxns
USD $4130.00
The SMARTer Stranded Total RNA-Seq Kit - Pico Input Mammalian is used to generate strand-specific RNA-seq libraries for Illumina sequencing using purified total RNA input ranging from 250 pg–10 ng. This kit takes advantage of SMARTer Stranded RNA-seq technology, based on our proprietary SMART (S witching M echanism a t the 5' end of R NA T emplate) technology, with the added benefits of locked nucleic acid (LNA) technology as in the SMART-Seq v4 kit. The integrated post-cDNA synthesis removal of abundant molecules originating from rRNA makes the workflow extremely sensitive with excellent reproducibility and low mapping to rRNA. This method was developed to work with either high- or low-quality total RNA and does not require additional rRNA removal methods or kits. Final libraries retain strand of origin information.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
635005
SMARTer® Stranded Total RNA-Seq Kit - Pico Input Mammalian
12 Rxns
USD $1442.00
The SMARTer Stranded Total RNA-Seq Kit - Pico Input Mammalian is used to generate strand-specific RNA-seq libraries for Illumina sequencing using purified total RNA input ranging from 250 pg–10 ng. This kit takes advantage of SMARTer Stranded RNA-seq technology, based on our proprietary S MART (Switching M echanism a t the 5' end of R NA T emplate) technology, with the added benefits of locked nucleic acid (LNA) technology as in the SMART-Seq v4 kit. The integrated post-cDNA synthesis removal of abundant molecules originating from rRNA makes the workflow extremely sensitive with excellent reproducibility and low mapping to rRNA. This method was developed to work with either high- or low-quality total RNA and does not require additional rRNA removal methods or kits. Final libraries retain strand of origin information.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634833
SMARTer® Ultra® Low RNA Kit for the Fluidigm® C1™ System, 10 IFCs
Each
USD $4233.00
The SMARTer Ultra Low RNA Kit for the Fluidigm C1 System allows high-quality cDNA synthesis starting from 96 single cells that have been isolated and processed with the Fluidigm C1 Single-Cell Auto Prep System. The kit utilizes SMART technology to enrich for full-length transcripts and maintain the true representation of the original mRNA transcripts (critical factors for transcriptome sequencing and gene expression analysis), and includes the Advantage 2 PCR Kit for PCR amplification and validation. The kit has been designed to prepare cDNA samples for transcriptome analysis on any Illumina Genome Analyzer, HiSeq, HiScan or MiSeq sequencing instrument.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.
634832
SMARTer® Ultra® Low RNA Kit for the Fluidigm® C1™ System, 2 IFCs
Each
USD $1170.00
The SMARTer Ultra Low RNA Kit for the Fluidigm C1 System allows high-quality cDNA synthesis starting from 96 single cells that have been isolated and processed with the Fluidigm C1 Single-Cell Auto Prep System. The kit utilizes SMART technology to enrich for full-length transcripts and maintain the true representation of the original mRNA transcripts (critical factors for transcriptome sequencing and gene expression analysis), and includes the Advantage 2 PCR Kit for PCR amplification and validation. The kit has been designed to prepare cDNA samples for transcriptome analysis on any Illumina Genome Analyzer, HiSeq, HiScan or MiSeq sequencing instrument.
Notice to purchaser
Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.