We use cookies to improve your browsing experience and provide meaningful content. Read our cookie policy. Accept
  •  Customer Login
  • Register
  •  View Cart (0)
  •  Customer Login
  • Register
  •  View Cart (0)

Takara Bio
  • Products
  • Services & Support
  • Learning centers
  • APPLICATIONS
  • About
  • Contact Us

Clontech Takara Cellartis

Close

  • ‹ Back to Epigenetic sequencing
  • ChIP-seq libraries for transcription factor analysis
  • ChIP-seq libraries from ssDNA
  • Full-length small RNA libraries
  • Methylated DNA-seq with MBD2
Product page ChIP-Seq kits product page
Home › Learning centers › Next-generation sequencing › Technical notes › Epigenetic sequencing › ChIP-seq libraries from ssDNA

Technical notes

  • DNA-seq
    • NGS library prep with enzymatic fragmentation
    • Comparing ThruPLEX FLEX EF to Kapa and NEBNext
    • Next-gen WGA method for CNV and SNV detection from single cells
    • Low-input whole-exome sequencing
    • DNA-seq from FFPE samples
    • Low cell number ChIP-seq using ThruPLEX DNA-Seq
    • Detection of low-frequency variants using ThruPLEX Tag-Seq FLEX
    • ThruPLEX FLEX outperforms NEBNext Ultra II
    • Streamlined DNA-seq from challenging samples
    • High-resolution CNV detection using PicoPLEX Gold DNA-Seq
    • ThruPLEX FLEX data sheet
    • Low-volume DNA shearing for ThruPLEX library prep
  • Immune Profiling
    • Track B-cell changes in your mouse model
    • Efficient and sensitive profiling of human B-cell receptor repertoire
    • TCRv2 kit validated for rhesus macaque samples
    • Improved TCR repertoire profiling from mouse samples (bulk)
    • TCR repertoire profiling from mouse samples (bulk)
    • BCR repertoire profiling from mouse samples (bulk)
    • Improved TCR repertoire profiling from human samples (bulk)
    • TCR repertoire profiling from human samples (single cells)
    • BCR repertoire profiling from human samples (bulk)
  • Epigenetic sequencing
    • ChIP-seq libraries for transcription factor analysis
    • ChIP-seq libraries from ssDNA
    • Full-length small RNA libraries
    • Methylated DNA-seq with MBD2
  • Reproductive health technologies
    • Embgenix ESM Screen
    • Embgenix PGT-A
New products
Need help?
Contact Sales
Product page ChIP-Seq kits product page
Tech Note

Ligation-free ChIP-seq library preparation

  • Ligation-free template switching technology
    Minimize sample handling in a single-tube workflow
  • Fast cross-linking reversal
    Reverse cross-link and recover DNA from ChIP experiments in one hour
  • Simplified protocol with post-PCR size selection
    Higher yield with a combined post-PCR size selection and cleanup step
  • Sensitive, reproducible data
    Libraries have high nonredundant rates, numbers of peaks identified, and overlap with ENCODE data
Introduction Results Conclusions Methods References

Introduction  

Pushing good science forward sometimes demands working through experimental challenges. Preparing next-generation sequencing (NGS) libraries from chromatin immunoprecipitation (ChIP) experiments can be one of those challenges due to the small amount of DNA available and the time required to prepare samples for sequencing. Most library preparation methods rely on ligation to add sequencing adapters when generating ChIP sequencing (ChIP-seq) libraries. However, these methods require double-stranded DNA (dsDNA) inputs, limiting which methods can be used to elute DNA from beads during ChIP or requiring additional preparation steps prior to library construction. The ChIP Elute Kit employs a simple and fast method for cross-linking reversal and eluting ChIP DNA. It generates single-stranded DNA (ssDNA) directly compatible with the DNA SMART ChIP-seq kit, which utilizes a modified version of SMART template-switching technology to provide a ligation-free method for addition of Illumina sequencing adapters. Template-switching technology allows for single-step adapter addition and has the sensitivity required for library preparation from picogram quantities of nucleic acids.

The ChIP Elute Kit and DNA SMART ChIP-seq kit are robust and reliable tools for ChIP-seq applications, particularly at low input levels (100 pg–10 ng). Using these two kits, high-quality library preparation can be completed in an efficient and time-saving manner.

Results  

Template-switching technology for DNA

DNA SMART technology eliminates the need for an adapter ligation step and associated cleanup during ChIP-seq library preparation. This improves library yield and maintains the complexity in the original DNA sample. The streamlined protocol is enabled by the SMARTScribe Reverse Transcriptase (RT) which copies the DNA template and adds a few additional nucleotides to the 3' end of the newly synthesized DNA. The carefully designed DNA SMART Oligonucleotide base-pairs with these additional nontemplate nucleotides and creates an extended template, enabling the SMARTScribe RT to continue replicating to the end of the oligonucleotide. Sequencing libraries are then amplified by PCR using primers containing Illumina adapters

DNA SMART ChIP-seq kit technology

Flowchart of technology in the DNA SMART ChIP-seq kit. This single-tube workflow allows users to generate Illumina-compatible libraries for ChIP-seq experiments. After library size selection and purification, the total time from input DNA to ChIP-seq library is approximately four hours.

Fast ChIP elution

The ChIP Elute Kit is a fast and simple tool for dissociation of the nuclear protein-DNA complexes (cross-linking reversal) and elution of genomic DNA fragments from ChIP experiments. Recovering purified DNA from ChIP can be a tedious aspect of traditional ChIP protocols and may need to be performed overnight; however, with the ChIP Elute Kit, purified ChIP DNA can be recovered as ssDNA in approximately one hour. ssDNA is compatible with downstream applications such as qPCR or ChIP-seq library preparation using the DNA SMART ChIP-seq kit. The ChIP-seq libraries generated using the ChIP Elute Kit are equivalent to those generated from longer, traditional methods of cross-linking reversal and elution, but in a significantly shorter time.

Sequencing metrics comparing the ChIP Elute Kit to traditional cross-linking reversal methods
Elution/cross-linking reversal method ChIP Elute Kit Traditional ChIP Elute Kit Traditional
Input amount 1 ng 0.25 ng
Library yield (nM) 21.4 16.4 37.3 28.1
Mapped to genome (%) 89.7 90.2 86.4 87.3
Mapped uniquely to genome (%) 71.6 73.2 70.2 71.1
Useful reads (uniquely mapped, nonduplicates; %) 66.0 67.2 58.1 59.0
Nonredundant rate 0.92 0.96 0.83 0.83
No. of peaks identified 37,610 36,924 39,525 37,134


Sequencing metrics comparing ChIP-seq libraries generated with ChIP Elute Kit or traditional cross-linking reversal methods
. ChIP was performed using an antibody against CTCF then DNA was eluted using the two different methods. 1 ng or 0.25 ng of the resulting DNA was then used to generate ChIP-seq libraries with the DNA SMART ChIP-seq kit using 13 PCR cycles for the 1-ng libraries and 16 PCR cycles for the 0.25-ng libraries. Across all sequencing metrics, ChIP DNA produced using the ChIP Elute Kit generated ChIP-seq libraries that were comparable to those produced using traditional, slow cross-linking reversal methods. Showing that the ChIP Elute Kit works well across a wide range of inputs in just one hour.

The peaks identified from libraries made from DNA eluted with either the ChIP Elute Kit or the traditional method are very similar and match those identified by the ENCODE project. The number of peaks identified is consistent across input levels for both the ChIP Elute Kit and traditional method, and the number of peaks identified by either method is similar for the same input level.

The shapes and locations of peaks are similar for different cross-linking reversal and elution methods and across input amounts

The shapes and locations of peaks are similar for different cross-linking reversal and elution methods and across input amounts. ChIP-seq libraries made from DNA eluted with either the ChIP Elute Kit or traditional method had high amounts of overlap in the number of peaks identified. The percent overlap of peaks identified in ChIP-seq libraries prepared from DNA isolated with the ChIP Elute Kit and traditional method were 90% and 89% for the 1 ng and 250 pg samples, respectively.

Protocol improvements for ChIP-seq library preparation

Contrary to typical library preparation protocols with an absolute requirement for a cleanup step between adapter ligation and PCR amplification of the library, the DNA SMART ChIP-seq kit uses a combined size-selection and cleanup step only after library amplification by PCR. The post-PCR size selection results in a higher yield and better library complexity (nonredundant rate) while maintaining the quality of the libraries.

Sequencing metrics comparing pre- and post-PCR size selection
Size selection pre-PCR post-PCR post-PCR
(single selection)
Library yield (nM) 10.9 17.2 26.9
No. uniquely mapped reads (million) 5.1 5.9 4.3
Nonredundant rate 0.75 0.85 0.89
Peaks identified with 3.85 M reads (uniquely mapped, nonduplicates) 32,827 34,011 33,398

 

Sequencing metrics from ChIP-seq libraries purified before or after amplification

Sequencing metrics from ChIP-seq libraries purified before or after amplification. ChIP was performed using an antibody against CTCF, then DNA was eluted using the traditional method. ChIP-seq libraries were generated from 200 pg of the ChIP DNA with size selection before or after library amplification (16 cycles of PCR). Size selection removed both small and large inserts (except for the single size selection sample indicated, which only removed small fragments/adapter dimers).

Performing size selection after amplification makes the workflow easier while generating data comparable to those generated using a pre-PCR size selection. The locations and shapes of the peaks identified using post-PCR size selection are indistinguishable from those reported by the ENCODE project.

Peak calling and electropherograms of pre- and post-PCR size selection libraries

Size selection before or after PCR amplification does not affect library quality. Peaks identified from pre- or post-PCR size selection and purification (Panel A) and electropherograms showing the different libraries generated using pre- or post-PCR size selection (Panel B) are shown.

Sensitive library production

The DNA SMART ChIP-seq kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented ssDNA or dsDNA. The number of unique, nonduplicate reads is high across all input levels, and the number of peaks identified is similar across input amounts.

Sequencing metrics from various amounts of input DNA
Input amount (ng) 4 1 0.5 0.25 0.1 0.05
No. of PCR cycles 12 13 14 15 17 18
Library yield (nM) 44.5 19.2 32.2 12.0 24.3 14.3
Mapped to genome (%) 91.9 91.0 91.0 91.1 90.7 90.2
Mapped uniquely to genome (%) 72.8 72.5 72.3 72.7 72.1 71.8
Useful reads (uniquely mapped, nonduplicates; %) 68.2 64.4 64.3 50.3 45.0 23.8
No. of peaks identified 16,738 16,811 16,366 17,277 16,584 19,601


Sequencing metrics from specific amounts of input DNA.
 ChIP was performed using an anti-H3K4me3 antibody and DNA was eluted using the traditional method. ChIP-seq libraries were then generated from different dilutions of the same dsDNA ChIP input sample. These libraries have very similar sequencing metrics, showing the high sensitivity and reproducibility of this kit.

Libraries generated with this kit have high reproducibility; the overlap between the number of peaks identified from technical replicates generated from the same amount of input DNA is >93% for input levels greater than 100 pg, and libraries generated from different input amounts have >94% overlap with each other. The complexity (the nonredundant rate) is also very high for these libraries.

ChIP-seq library complexity and reproducibility from low-input DNA.

ChIP-seq library complexity and reproducibility is maintained across input amounts. The reproducibility between technical replicates was similar across input amounts (Panel A). The nonredundant rate (normalized for 10 million uniquely mapped reads) was well above the standard recommended by the ENCODE project (0.8) for inputs >0.5 ng (Panel B; error bars indicate the standard deviation of two technical replicates). Compared to the 4-ng library, the number of peaks identified was similar across lower input libraries (Panel C). The shape and locations of the peaks were similar across input levels and matched very well to ENCODE data (293 cells, anti-H3K4me3 antibody, U. Washington), even for as little as 50 pg of input DNA (Panel D).

Reproducible libraries from specific numbers of cells

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations. Typically, researchers must use the entire ChIP DNA sample obtained for sequencing library preparation. With DNA SMART technology, ChIP-seq data from total (unquantified) ChIP DNA is consistent across different starting cell numbers.

Sequencing metrics from total DNA from specified numbers of cells
Input amount (millions of cells) 1 0.2 0.05 0.01
No. of PCR cycles 15 18 18 18
Library yield (nM) 86.7 101 44.6 20.5
Mapped to genome (%) 92.7 88.6 84.3 75.8
Mapped uniquely to genome (%) 79.0 74.8 70.4 59.6
Useful reads (uniquely mapped, nonduplicates; %) 66.8 63.5 49.9 34.0
Nonredundant rate 0.85 0.85 0.71 0.57
No. of peaks identified 19,459 19,339 18,549 22,564


The DNA SMART ChIP-seq kit generates high-quality libraries from low cell number ChIP experiments.
 Total ssDNA recovered using the ChIP Elute Kit from ChIP experiments using an anti-H3K4me3 antibody with the number of cells indicated was used as input for the DNA SMART ChIP-seq kit. Mapping statistics were very good across all input levels. DNA SMART ChIP-seq kit libraries maintain consistent representation of sequences even at the lowest input levels. Between 86–91% of the identified peaks overlapped between different input amounts. Across all cell inputs, the DNA SMART ChIP-seq kit generates data that matches well with the reported data from the ENCODE project (>87 % overlap in peaks).

ChIP-seq library complexity and reproducibility from total DNA from small Amounts of cells; DNA SMART ChIP-seq library overlap with ENCODE data

Peak overlap between libraries generated from various inputs. Peaks from different numbers of cells were identified using 6 million (for 10,000 cells) or 9–10 million (for 50,000–1,000,000 cells) uniquely mapped reads. There was a high amount of overlap across the number of input cells (Panel A). The peaks were of similar shape across cell inputs and matched the peaks obtained by the ENCODE project (293 cells, anti-H3K4me3 antibody, U. Washington; Panel B). Additionally, the total number of peaks overlapping with those identified in the ENCODE project was high (Panel C).

Conclusions  

The modified template switching technology at the core of the DNA SMART ChIP-seq kit provides a sensitive means for generating sequencing libraries in a ligation-independent manner from either ssDNA or dsDNA templates. The combined post-PCR library size selection and cleanup step generates libraries with higher yields than if size selection and cleanup are performed before library amplification, thus simplifying the workflow, and making this kit ideal for low-input DNA samples. The ChIP Elute Kit minimizes the time needed to reverse cross-link, elute, purify, and concentrate ChIP DNA. This makes it faster to get to downstream applications, like ChIP-seq. Together the ChIP Elute Kit and DNA SMART ChIP-seq kit generate sensitive, robust, reproducible ChIP-seq libraries for Illumina sequencing.

Methods  

For ChIP assays, HEK 293T cells were grown to 80% confluence and fixed with 1% formaldehyde for 10 minutes. ChIP was performed with ChIP-grade anti-H3K4me3 or anti-CTCF antibodies according to standard methods (chromatin shearing by sonication with Bioruptor Pico; Diagenode). After washes, DNA-protein complexes immobilized to Protein A/G agarose beads (Santa Cruz Biotechnologies, Inc.) were processed according to the traditional method (see below) or the ChIP Elute Kit.

Traditional ChIP DNA recovery method: DNA-protein complexes were eluted from the beads in SDS buffer (1% SDS, 0.1 M NaHCO3) then DNA-protein cross-links were reversed in the presence of 250 mM NaCl at 65°C overnight. Finally, a Proteinase K treatment was performed to digest proteins. See (Massie and Mills 2012) for an example of this method. After elution and cross-linking reversal, the DNA was purified and concentrated with a Macherey-Nagel NucleoSpin Gel and PCR Clean-Up kit (using the NTB buffer; available separately).

Samples processed with ChIP Elute Kit were handled according to the kit protocol. The ChIP Elute Kit includes DNA clean-up and concentration as part of the protocol, additional purification prior to sequencing library preparation is not necessary.

For a direct comparison between the ChIP Elute Kit and the traditional method, beads with bound complexes were split after the last wash step, and half of the material was processed with the traditional method, while the other half was processed with the ChIP Elute Kit.

Sequencing libraries were generated using the DNA SMART ChIP-seq kit and size selection was performed with AMPure XP beads (Beckman Coulter) using Option 1 or Option 4 as described in the DNA SMART ChIP-seq kit User Manual. Sequencing was carried out on Illumina MiSeq® or HiSeq® 2500 instruments. All runs were paired-end sequenced using the Custom Read2 Seq Primer from the DNA SMART ChIP-seq kit for some runs.

Mapping of reads (unpaired) to the human genome (hg19) was performed using Bowtie2 with default settings (plus trimming of the first three 5' nucleotides of the reads obtained with the Read Primer 1). Uniquely mapping reads were selected, and the SAM files were sorted and converted to BAM files using SAMTOOLS. Peaks were identified using MACS version 1.4 (default settings except the p-value cutoff set at 1 x 10-7). Raw data generated by the ENCODE consortium were downloaded as fastq files from http://genome.ucsc.edu/ENCODE/downloads.html and analyzed similarly to the data generated with the DNA SMART ChIP-Seq Kit. Reads and peaks were visualized using the UCSC genome browser.

References  

Massie, C. E. & Mills, I. G. in Transcr. Regul. Methods Protoc. (Vancura, A.) 157–173 (Springer New York, 2012). doi:10.1007/978-1-61779-376-9_11

Related products

Cat. # Product Size Price License Quantity Details
634865 DNA SMART™ ChIP-Seq Kit - 12 12 Rxns USD $748.00

License Statement

ID Number  
270
This Product is protected by one or more patents from the family consisting of: US9410173, DE602013058951.8, US11001882, EP2912197, FR2912197, UK2912197, JP6338221and any corresponding patents, divisionals, continuations, patent applications and foreign filings sharing common priority with the same family.

ChIP sequencing (ChIP-seq) combines chromatin immunoprecipitation (ChIP) with next-generation sequencing (NGS) to identify the location of protein binding to DNA. The DNA SMART ChIP-Seq Kit generates indexed ChIP-seq libraries suitable for NGS on Illumina sequencing platforms. Library complexity is preserved from as little as 500 pg of double-stranded or single-stranded input DNA. The kit utilizes Clontech's DNA SMART technology; sequencing libraries are generated without the need for enzymatic cleanup or adapter ligations. All of the necessary reagents for producing ChIP-seq libraries are provided in this kit, including primer sets that contain Illumina high-throughput indexes. There are three different versions of the kit depending on the number and specific Illumina indexes desired. For more information on the indexes supplied in each kit visit: www.takarabio.com.

Notice to purchaser

Our products are to be used for Research Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.

Documents Components You May Also Like Image Data Resources

Back

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR
The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR. Compared to other protocols that perform size selection before PCR amplification, post-PCR size selection results in a higher yield while maintaining the quality of the libraries.

Back

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit
Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit. The location and shape of the peaks identified using post-PCR size selection still matched reported ENCODE data (Panel A). Electropherograms show the different libraries generated using pre- or post-PCR size selection (Panel B).

Back

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA
The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA. The number of unique, non-duplicate reads is high across all input levels, and the number of peaks identified is similar across input amounts.

Back

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility
Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility. The reproducibility between technical replicates was similar across input amounts (Panel A). The non-redundant rate (normalized for 10 million uniquely mapped reads) was well above the standard recommended by the ENCODE project (0.8) for inputs >0.5 ng (Panel B; error bars indicate the standard deviation of two technical replicates). Compared to the 4 ng library, the number of peaks were similar across lower input libraries (Panel C). The shape and location of the peaks was similar across input levels, and matched very well to ENCODE data (293 cells, anti-H3K4me3 antibody, U. Washington), even for as little as 50 pg input DNA (Panel D).

Back

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels
DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels. Peaks from different numbers of cells were identified using 6 million (for 10,000 cells) or 9–10 million (for 50,000–1,000,000 cells) uniquely mapped reads. There was a high amount of overlap across the number of input cells (Panel A). The peaks were of similar shape across cell inputs and matched the peaks obtained by the ENCODE project (293 cells, anti-H3K4me3 antibody, U. Washington; Panel B). Additionally, the total number of peaks overlapping with those identified in the ENCODE project was high (Panel C).

Back

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations
Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations. Typically, researchers must use the entire ChIP DNA sample obtained for sequencing library preparation. With DNA SMART technology, ChIP-seq data from total (unquantified) ChIP DNA is consistent across different starting cell numbers.

Back

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment
The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment.

Back

Flowchart of technology in the DNA SMART ChIP-Seq Kit

Flowchart of technology in the DNA SMART ChIP-Seq Kit
Flowchart of technology in the DNA SMART ChIP-Seq Kit. This single-tube workflow allows users to generate Illumina-compatible libraries for ChIP-seq experiments. After library size selection and purification, the total time from input DNA to ChIP-seq library is approximately four hours.

Back

634865: DNA SMART ChIP-Seq Kit - 12

634865: DNA SMART ChIP-Seq Kit - 12
634866 DNA SMART™ ChIP-Seq Kit - 48 A 48 Rxns USD $2360.00

License Statement

ID Number  
270
This Product is protected by one or more patents from the family consisting of: US9410173, DE602013058951.8, US11001882, EP2912197, FR2912197, UK2912197, JP6338221and any corresponding patents, divisionals, continuations, patent applications and foreign filings sharing common priority with the same family.

ChIP sequencing (ChIP-seq) combines chromatin immunoprecipitation (ChIP) with next-generation sequencing (NGS) to identify the location of protein binding to DNA. The DNA SMART ChIP-Seq Kit generates indexed ChIP-seq libraries suitable for NGS on Illumina sequencing platforms. Library complexity is preserved from as little as 500 pg of double-stranded or single-stranded input DNA. The kit utilizes Takara Bio's DNA SMART technology; sequencing libraries are generated without the need for enzymatic cleanup or adapter ligations. All of the necessary reagents for producing ChIP-seq libraries are provided in this kit, including primer sets that contain Illumina high-throughput indexes. There are three different versions of the kit depending on the number and specific Illumina indexes desired.

Notice to purchaser

Our products are to be used for Research Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.

Documents Components You May Also Like Image Data Resources

Back

634866: DNA SMART ChIP-Seq Kit - 48 A

634866: DNA SMART ChIP-Seq Kit - 48 A

Back

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR
The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR. Compared to other protocols that perform size selection before PCR amplification, post-PCR size selection results in a higher yield while maintaining the quality of the libraries.

Back

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit
Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit. The location and shape of the peaks identified using post-PCR size selection still matched reported ENCODE data (Panel A). Electropherograms show the different libraries generated using pre- or post-PCR size selection (Panel B).

Back

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA
The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA. The number of unique, non-duplicate reads is high across all input levels, and the number of peaks identified is similar across input amounts.

Back

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility
Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility. The reproducibility between technical replicates was similar across input amounts (Panel A). The non-redundant rate (normalized for 10 million uniquely mapped reads) was well above the standard recommended by the ENCODE project (0.8) for inputs >0.5 ng (Panel B; error bars indicate the standard deviation of two technical replicates). Compared to the 4 ng library, the number of peaks were similar across lower input libraries (Panel C). The shape and location of the peaks was similar across input levels, and matched very well to ENCODE data (293 cells, anti-H3K4me3 antibody, U. Washington), even for as little as 50 pg input DNA (Panel D).

Back

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels
DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels. Peaks from different numbers of cells were identified using 6 million (for 10,000 cells) or 9–10 million (for 50,000–1,000,000 cells) uniquely mapped reads. There was a high amount of overlap across the number of input cells (Panel A). The peaks were of similar shape across cell inputs and matched the peaks obtained by the ENCODE project (293 cells, anti-H3K4me3 antibody, U. Washington; Panel B). Additionally, the total number of peaks overlapping with those identified in the ENCODE project was high (Panel C).

Back

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations
Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations. Typically, researchers must use the entire ChIP DNA sample obtained for sequencing library preparation. With DNA SMART technology, ChIP-seq data from total (unquantified) ChIP DNA is consistent across different starting cell numbers.

Back

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment
The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment.

Back

Flowchart of technology in the DNA SMART ChIP-Seq Kit

Flowchart of technology in the DNA SMART ChIP-Seq Kit
Flowchart of technology in the DNA SMART ChIP-Seq Kit. This single-tube workflow allows users to generate Illumina-compatible libraries for ChIP-seq experiments. After library size selection and purification, the total time from input DNA to ChIP-seq library is approximately four hours.
634867 DNA SMART™ ChIP-Seq Kit - 48 B 48 Rxns USD $2368.00

License Statement

ID Number  
270
This Product is protected by one or more patents from the family consisting of: US9410173, DE602013058951.8, US11001882, EP2912197, FR2912197, UK2912197, JP6338221and any corresponding patents, divisionals, continuations, patent applications and foreign filings sharing common priority with the same family.

ChIP sequencing (ChIP-seq) combines chromatin immunoprecipitation (ChIP) with next-generation sequencing (NGS) to identify the location of protein binding to DNA. The DNA SMART ChIP-Seq Kit generates indexed ChIP-seq libraries suitable for NGS on Illumina sequencing platforms. Library complexity is preserved from as little as 500 pg of double-stranded or single-stranded input DNA. The kit utilizes Clontech's DNA SMART technology; sequencing libraries are generated without the need for enzymatic cleanup or adapter ligations. All of the necessary reagents for producing ChIP-seq libraries are provided in this kit, including primer sets that contain Illumina high-throughput indexes. There are three different versions of the kit depending on the number and specific Illumina indexes desired. For more information on the indexes supplied in each kit visit: www.takarabio.com.

Notice to purchaser

Our products are to be used for Research Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.

Documents Components You May Also Like Image Data Resources

Back

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR

The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR
The DNA SMART ChIP-Seq Kit uses a combined size selection and clean-up step after library amplification by PCR. Compared to other protocols that perform size selection before PCR amplification, post-PCR size selection results in a higher yield while maintaining the quality of the libraries.

Back

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit

Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit
Performing size selection after amplification does not alter the quality of the data generated by the DNA SMART ChIP-Seq Kit. The location and shape of the peaks identified using post-PCR size selection still matched reported ENCODE data (Panel A). Electropherograms show the different libraries generated using pre- or post-PCR size selection (Panel B).

Back

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA

The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA
The DNA SMART ChIP-Seq Kit has the sensitivity to generate sequencing libraries from very small amounts of fragmented DNA. The number of unique, non-duplicate reads is high across all input levels, and the number of peaks identified is similar across input amounts.

Back

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility

Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility
Libraries generated with the DNA SMART ChIP-Seq Kit have high reproducibility. The reproducibility between technical replicates was similar across input amounts (Panel A). The non-redundant rate (normalized for 10 million uniquely mapped reads) was well above the standard recommended by the ENCODE project (0.8) for inputs >0.5 ng (Panel B; error bars indicate the standard deviation of two technical replicates). Compared to the 4 ng library, the number of peaks were similar across lower input libraries (Panel C). The shape and location of the peaks was similar across input levels, and matched very well to ENCODE data (293 cells, anti-H3K4me3 antibody, U. Washington), even for as little as 50 pg input DNA (Panel D).

Back

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels

DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels
DNA SMART ChIP-Seq Kit libraries maintain consistent representation of sequences even at the lowest input levels. Peaks from different numbers of cells were identified using 6 million (for 10,000 cells) or 9–10 million (for 50,000–1,000,000 cells) uniquely mapped reads. There was a high amount of overlap across the number of input cells (Panel A). The peaks were of similar shape across cell inputs and matched the peaks obtained by the ENCODE project (293 cells, anti-H3K4me3 antibody, U. Washington; Panel B). Additionally, the total number of peaks overlapping with those identified in the ENCODE project was high (Panel C).

Back

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations

Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations
Exact quantification of DNA obtained by ChIP can be very difficult due to the low concentrations. Typically, researchers must use the entire ChIP DNA sample obtained for sequencing library preparation. With DNA SMART technology, ChIP-seq data from total (unquantified) ChIP DNA is consistent across different starting cell numbers.

Back

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment

The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment
The DNA SMART ChIP-Seq Kit comes with reagents that have color-coded caps for easier identification while carrying out an experiment.

Back

Flowchart of technology in the DNA SMART ChIP-Seq Kit

Flowchart of technology in the DNA SMART ChIP-Seq Kit
Flowchart of technology in the DNA SMART ChIP-Seq Kit. This single-tube workflow allows users to generate Illumina-compatible libraries for ChIP-seq experiments. After library size selection and purification, the total time from input DNA to ChIP-seq library is approximately four hours.

Back

634867: DNA SMART ChIP-Seq Kit - 48 B

634867: DNA SMART ChIP-Seq Kit - 48 B
634887 ChIP Elute Kit 50 Rxns USD $484.00

The ChIP Elute Kit is designed to be used downstream of a chromatin immunoprecipitation (ChIP) assay to elute DNA
associated with the antibody. The ChIP Elute Kit allows for simultaneous elution and crosslinking reversal of nuclear protein-DNA complexes in a single step. The resulting DNA is single stranded (ssDNA) and is purified and concentrated with the ChIP-grade reagents provided in the kit. The output from this kit is directly compatible with ChIP-seq library preparation using the DNA SMART ChIP-Seq Kit. The DNA SMART ChIP-Seq Kit generates sequencing libraries compatible with Illumina platforms from single-stranded or double-stranded fragmented DNA.

Notice to purchaser

Our products are to be used for Research Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.

Documents Components You May Also Like Image Data Resources

Back

634887: ChIP Elute Kit

634887: ChIP Elute Kit

Takara Bio USA, Inc.
United States/Canada: +1.800.662.2566 • Asia Pacific: +1.650.919.7300 • Europe: +33.(0)1.3904.6880 • Japan: +81.(0)77.565.6999
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. © 2025 Takara Bio Inc. All Rights Reserved. All trademarks are the property of Takara Bio Inc. or its affiliate(s) in the U.S. and/or other countries or their respective owners. Certain trademarks may not be registered in all jurisdictions. Additional product, intellectual property, and restricted use information is available at takarabio.com.

Takara Bio

Takara Bio USA, Inc. provides kits, reagents, instruments, and services that help researchers explore questions about gene discovery, regulation, and function. As a member of the Takara Bio Group, Takara Bio USA is part of a company that holds a leadership position in the global market and is committed to improving the human condition through biotechnology. Our mission is to develop high-quality innovative tools and services to accelerate discovery.

FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES (EXCEPT AS SPECIFICALLY NOTED).

Support
  • Contact us
  • Technical support
  • Customer service
  • Shipping & delivery
  • Sales
  • Feedback
Products
  • New products
  • Special offers
  • Instrument & reagent services
Learning centers
  • NGS
  • Gene function
  • Stem cell research
  • Protein research
  • PCR
  • Cloning
  • Nucleic acid purification
About
  • Our brands
  • Careers
  • Events
  • Blog
  • Need help?
  • Announcements
  • Quality and compliance
  • That's Good Science!
Facebook Twitter  LinkedIn

logo strip white

©2025 Takara Bio Inc. All Rights Reserved.

Region - North America Privacy Policy Terms and Conditions Terms of Use

Top



  • COVID-19 research
  • Viral detection with qPCR
  • SARS-CoV-2 pseudovirus
  • Human ACE2 stable cell line
  • Viral RNA isolation
  • Viral and host sequencing
  • Vaccine development
  • CRISPR screening
  • Drug discovery
  • Immune profiling
  • Publications
  • Next-generation sequencing
  • Spatial omics
  • RNA-seq
  • DNA-seq
  • Single-cell NGS automation
  • Reproductive health
  • Bioinformatics tools
  • Immune profiling
  • Real-time PCR
  • Great value master mixes
  • Signature enzymes
  • High-throughput real-time PCR solutions
  • Detection assays
  • References, standards, and buffers
  • Stem cell research
  • Media, differentiation kits, and matrices
  • Stem cells and stem cell-derived cells
  • mRNA and cDNA synthesis
  • In vitro transcription
  • cDNA synthesis kits
  • Reverse transcriptases
  • RACE kits
  • Purified cDNA & genomic DNA
  • Purified total RNA and mRNA
  • PCR
  • Most popular polymerases
  • High-yield PCR
  • High-fidelity PCR
  • GC rich PCR
  • PCR master mixes
  • Cloning
  • In-Fusion seamless cloning
  • Competent cells
  • Ligation kits
  • Restriction enzymes
  • Nucleic acid purification
  • Automated platforms
  • Plasmid purification kits
  • Genomic DNA purification kits
  • DNA cleanup kits
  • RNA purification kits
  • Gene function
  • Gene editing
  • Viral transduction
  • Fluorescent proteins
  • T-cell transduction and culture
  • Tet-inducible expression systems
  • Transfection reagents
  • Cell biology assays
  • Protein research
  • Purification products
  • Two-hybrid and one-hybrid systems
  • Mass spectrometry reagents
  • Antibodies and ELISAs
  • Primary antibodies and ELISAs by research area
  • Fluorescent protein antibodies
  • New products
  • Special offers
  • OEM
  • Portfolio
  • Process
  • Facilities
  • Request samples
  • FAQs
  • Instrument services
  • Apollo services
  • ICELL8 services
  • SmartChip ND system services
  • Gene and cell therapy manufacturing services
  • Services
  • Facilities
  • Our process
  • Resources
  • Customer service
  • Sales
  • Make an appointment with your sales rep
  • Shipping & delivery
  • Technical support
  • Feedback
  • Online tools
  • GoStix Plus FAQs
  • Partnering & Licensing
  • Vector information
  • Vector document overview
  • Vector document finder
Takara Bio's award-winning GMP-compliant manufacturing facility in Kusatsu, Shiga, Japan.

Partner with Takara Bio!

Takara Bio is proud to offer GMP-grade manufacturing capabilities at our award-winning facility in Kusatsu, Shiga, Japan.

  • Automation systems
  • Shasta Single Cell System introduction
  • SmartChip Real-Time PCR System introduction
  • ICELL8 introduction
  • Next-generation sequencing
  • RNA-seq
  • Technical notes
  • Technology and application overviews
  • FAQs and tips
  • DNA-seq protocols
  • Bioinformatics resources
  • Webinars
  • Spatial biology
  • Real-time PCR
  • Download qPCR resources
  • Overview
  • Reaction size guidelines
  • Guest webinar: extraction-free SARS-CoV-2 detection
  • Technical notes
  • Nucleic acid purification
  • Nucleic acid extraction webinars
  • Product demonstration videos
  • Product finder
  • Plasmid kit selection guide
  • RNA purification kit finder
  • mRNA and cDNA synthesis
  • mRNA synthesis
  • cDNA synthesis
  • PCR
  • Citations
  • PCR selection guide
  • Technical notes
  • FAQ
  • Cloning
  • Automated In-Fusion Cloning
  • In-Fusion Cloning general information
  • Primer design and other tools
  • In‑Fusion Cloning tips and FAQs
  • Applications and technical notes
  • Stem cell research
  • Overview
  • Protocols
  • Technical notes
  • Gene function
  • Gene editing
  • Viral transduction
  • T-cell transduction and culture
  • Inducible systems
  • Cell biology assays
  • Protein research
  • Capturem technology
  • Antibody immunoprecipitation
  • His-tag purification
  • Other tag purification
  • Expression systems
  • Antibodies and ELISA
  • Molecular diagnostics
  • Interview: adapting to change with Takara Bio
  • Applications
  • Solutions
  • Partnering
  • Contact us
  • mRNA and protein therapeutics
  • Characterizing the viral genome and host response
  • Identifying and cloning protein targets
  • Expressing and purifying protein targets
  • Immunizing mice and optimizing vaccines
  • Pathogen detection
  • Sample prep
  • Detection methods
  • Identification and characterization
  • SARS-CoV-2
  • Antibiotic-resistant bacteria
  • Food crop pathogens
  • Waterborne disease outbreaks
  • Viral-induced cancer
  • Immunotherapy research
  • T-cell therapy
  • Antibody therapeutics
  • T-cell receptor profiling
  • TBI initiatives in cancer therapy
  • Cancer research
  • Kickstart your cancer research with long-read sequencing
  • Sample prep from FFPE tissue
  • Sample prep from plasma
  • Cancer biomarker quantification
  • Single cancer cell analysis
  • Cancer transcriptome analysis
  • Cancer genomics and epigenomics
  • HLA typing in cancer
  • Gene editing for cancer therapy/drug discovery
  • Alzheimer's disease research
  • Antibody engineering
  • Sample prep from FFPE tissue
  • Single-cell sequencing
  • Reproductive health technologies
  • Embgenix FAQs
  • Preimplantation genetic testing
  • ESM partnership program
  • ESM Collection Kit forms
  • Infectious diseases
  • Develop vaccines for HIV
Create a web account with us

Log in to enjoy additional benefits

Want to save this information?

An account with takarabio.com entitles you to extra features such as:

•  Creating and saving shopping carts
•  Keeping a list of your products of interest
•  Saving all of your favorite pages on the site*
•  Accessing restricted content

*Save favorites by clicking the star () in the top right corner of each page while you're logged in.

Create an account to get started

  • BioView blog
  • Automation
  • Cancer research
  • Career spotlights
  • Current events
  • Customer stories
  • Gene editing
  • Research news
  • Single-cell analysis
  • Stem cell research
  • Tips and troubleshooting
  • Women in STEM
  • That's Good Support!
  • About our blog
  • That's Good Science!
  • SMART-Seq Pro Biomarker Discovery Contest
  • DNA extraction educational activity
  • That's Good Science Podcast
  • Season one
  • Season two
  • Season three
  • Our brands
  • Our history
  • In the news
  • Events
  • Biomarker discovery events
  • Calendar
  • Conferences
  • Speak with us
  • Careers
  • Company benefits
  • Trademarks
  • License statements
  • Quality statement
  • HQ-grade reagents
  • International Contacts by Region
  • United States and Canada
  • China
  • Japan
  • Korea
  • Europe
  • India
  • Affiliates & distributors
  • Need help?
  • Privacy request
  • Website FAQs

That's GOOD Science!

What does it take to generate good science? Careful planning, dedicated researchers, and the right tools. At Takara Bio, we thoughtfully develop exceptional products to tackle your most challenging research problems, and have an expert team of technical support professionals to help you along the way, all at superior value.

Explore what makes good science possible

 Customer Login
 View Cart (0)
Takara Bio
  • Home
  • Products
  • Services & Support
  • Learning centers
  • APPLICATIONS
  • About
  • Contact Us
  •  Customer Login
  • Register
  •  View Cart (0)

Takara Bio USA, Inc. provides kits, reagents, instruments, and services that help researchers explore questions about gene discovery, regulation, and function. As a member of the Takara Bio Group, Takara Bio USA is part of a company that holds a leadership position in the global market and is committed to improving the human condition through biotechnology. Our mission is to develop high-quality innovative tools and services to accelerate discovery.

FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES (EXCEPT AS SPECIFICALLY NOTED).

Clontech, TaKaRa, cellartis

  • Products
  • COVID-19 research
  • Next-generation sequencing
  • Real-time PCR
  • Stem cell research
  • mRNA and cDNA synthesis
  • PCR
  • Cloning
  • Nucleic acid purification
  • Gene function
  • Protein research
  • Antibodies and ELISA
  • New products
  • Special offers
  • COVID-19 research
  • Viral detection with qPCR
  • SARS-CoV-2 pseudovirus
  • Human ACE2 stable cell line
  • Viral RNA isolation
  • Viral and host sequencing
  • Vaccine development
  • CRISPR screening
  • Drug discovery
  • Immune profiling
  • Publications
  • Next-generation sequencing
  • Spatial omics
  • RNA-seq
  • DNA-seq
  • Single-cell NGS automation
  • Reproductive health
  • Bioinformatics tools
  • Immune profiling
  • Real-time PCR
  • Great value master mixes
  • Signature enzymes
  • High-throughput real-time PCR solutions
  • Detection assays
  • References, standards, and buffers
  • Stem cell research
  • Media, differentiation kits, and matrices
  • Stem cells and stem cell-derived cells
  • mRNA and cDNA synthesis
  • In vitro transcription
  • cDNA synthesis kits
  • Reverse transcriptases
  • RACE kits
  • Purified cDNA & genomic DNA
  • Purified total RNA and mRNA
  • PCR
  • Most popular polymerases
  • High-yield PCR
  • High-fidelity PCR
  • GC rich PCR
  • PCR master mixes
  • Cloning
  • In-Fusion seamless cloning
  • Competent cells
  • Ligation kits
  • Restriction enzymes
  • Nucleic acid purification
  • Automated platforms
  • Plasmid purification kits
  • Genomic DNA purification kits
  • DNA cleanup kits
  • RNA purification kits
  • Gene function
  • Gene editing
  • Viral transduction
  • Fluorescent proteins
  • T-cell transduction and culture
  • Tet-inducible expression systems
  • Transfection reagents
  • Cell biology assays
  • Protein research
  • Purification products
  • Two-hybrid and one-hybrid systems
  • Mass spectrometry reagents
  • Antibodies and ELISA
  • Primary antibodies and ELISAs by research area
  • Fluorescent protein antibodies
  • Services & Support
  • OEM
  • Instrument services
  • Gene and cell therapy manufacturing
  • Customer service
  • Sales
  • Shipping & delivery
  • Technical support
  • Feedback
  • Online tools
  • Partnering & Licensing
  • Vector information
  • OEM
  • Portfolio
  • Process
  • Facilities
  • Request samples
  • FAQs
  • Instrument services
  • Apollo services
  • ICELL8 services
  • SmartChip ND system services
  • Gene and cell therapy manufacturing
  • Services
  • Facilities
  • Our process
  • Resources
  • Sales
  • Make an appointment with your sales rep
  • Online tools
  • GoStix Plus FAQs
  • Vector information
  • Vector document overview
  • Vector document finder
  • Learning centers
  • Automation systems
  • Next-generation sequencing
  • Spatial biology
  • Real-time PCR
  • Nucleic acid purification
  • mRNA and cDNA synthesis
  • PCR
  • Cloning
  • Stem cell research
  • Gene function
  • Protein research
  • Antibodies and ELISA
  • Automation systems
  • Shasta Single Cell System introduction
  • SmartChip Real-Time PCR System introduction
  • ICELL8 introduction
  • Next-generation sequencing
  • RNA-seq
  • Technical notes
  • Technology and application overviews
  • FAQs and tips
  • DNA-seq protocols
  • Bioinformatics resources
  • Webinars
  • Real-time PCR
  • Download qPCR resources
  • Overview
  • Reaction size guidelines
  • Guest webinar: extraction-free SARS-CoV-2 detection
  • Technical notes
  • Nucleic acid purification
  • Nucleic acid extraction webinars
  • Product demonstration videos
  • Product finder
  • Plasmid kit selection guide
  • RNA purification kit finder
  • mRNA and cDNA synthesis
  • mRNA synthesis
  • cDNA synthesis
  • PCR
  • Citations
  • PCR selection guide
  • Technical notes
  • FAQ
  • Cloning
  • Automated In-Fusion Cloning
  • In-Fusion Cloning general information
  • Primer design and other tools
  • In‑Fusion Cloning tips and FAQs
  • Applications and technical notes
  • Stem cell research
  • Overview
  • Protocols
  • Technical notes
  • Gene function
  • Gene editing
  • Viral transduction
  • T-cell transduction and culture
  • Inducible systems
  • Cell biology assays
  • Protein research
  • Capturem technology
  • Antibody immunoprecipitation
  • His-tag purification
  • Other tag purification
  • Expression systems
  • APPLICATIONS
  • Molecular diagnostics
  • mRNA and protein therapeutics
  • Pathogen detection
  • Immunotherapy research
  • Cancer research
  • Alzheimer's disease research
  • Reproductive health technologies
  • Infectious diseases
  • Molecular diagnostics
  • Interview: adapting to change with Takara Bio
  • Applications
  • Solutions
  • Partnering
  • Contact us
  • mRNA and protein therapeutics
  • Characterizing the viral genome and host response
  • Identifying and cloning protein targets
  • Expressing and purifying protein targets
  • Immunizing mice and optimizing vaccines
  • Pathogen detection
  • Sample prep
  • Detection methods
  • Identification and characterization
  • SARS-CoV-2
  • Antibiotic-resistant bacteria
  • Food crop pathogens
  • Waterborne disease outbreaks
  • Viral-induced cancer
  • Immunotherapy research
  • T-cell therapy
  • Antibody therapeutics
  • T-cell receptor profiling
  • TBI initiatives in cancer therapy
  • Cancer research
  • Kickstart your cancer research with long-read sequencing
  • Sample prep from FFPE tissue
  • Sample prep from plasma
  • Cancer biomarker quantification
  • Single cancer cell analysis
  • Cancer transcriptome analysis
  • Cancer genomics and epigenomics
  • HLA typing in cancer
  • Gene editing for cancer therapy/drug discovery
  • Alzheimer's disease research
  • Antibody engineering
  • Sample prep from FFPE tissue
  • Single-cell sequencing
  • Reproductive health technologies
  • Embgenix FAQs
  • Preimplantation genetic testing
  • ESM partnership program
  • ESM Collection Kit forms
  • Infectious diseases
  • Develop vaccines for HIV
  • About
  • BioView blog
  • That's Good Science!
  • Our brands
  • Our history
  • In the news
  • Events
  • Careers
  • Trademarks
  • License statements
  • Quality and compliance
  • HQ-grade reagents
  • International Contacts by Region
  • Need help?
  • Website FAQs
  • BioView blog
  • Automation
  • Cancer research
  • Career spotlights
  • Current events
  • Customer stories
  • Gene editing
  • Research news
  • Single-cell analysis
  • Stem cell research
  • Tips and troubleshooting
  • Women in STEM
  • That's Good Support!
  • About our blog
  • That's Good Science!
  • SMART-Seq Pro Biomarker Discovery Contest
  • DNA extraction educational activity
  • That's Good Science Podcast
  • Season one
  • Season two
  • Season three
  • Events
  • Biomarker discovery events
  • Calendar
  • Conferences
  • Speak with us
  • Careers
  • Company benefits
  • International Contacts by Region
  • United States and Canada
  • China
  • Japan
  • Korea
  • Europe
  • India
  • Affiliates & distributors
  • Need help?
  • Privacy request
Takara Bio
  • Products
  • Services & Support
  • Learning centers
  • APPLICATIONS
  • About
  • Contact Us