NucleoVac 24 Vacuum Manifold

Vacuum manifold for processing NucleoSpin or NucleoSnap silica columns in parallel for nucleic acid purification by vacuum.

The NucleoVac 24 Vacuum Manifold allows the parallel processing of silica columns for nucleic acid purification by vacuum. Silica columns (e.g., NucleoSpin and NucleoSnap columns) can be attached to the upper Luer openings of the vacuum manifold. The binding and washing steps of the NucleoSpin or NucleoSnap procedures are carried out by vacuum instead of centrifugation, enabling time-saving protocols (NucleoSpin products) and the processing of large sample volumes (NucleoSnap products).

The NucleoVac 24 Vacuum Manifold allows the parallel processing of silica columns for nucleic acid purification by vacuum. Silica columns (e.g., NucleoSpin and NucleoSnap columns) can be attached to the upper Luer openings of the vacuum manifold. The binding and washing steps of the NucleoSpin or NucleoSnap procedures are carried out by vacuum instead of centrifugation, enabling time-saving protocols (NucleoSpin products) and the processing of large sample volumes (NucleoSnap products).

Setting up the NucleoVac 24

Setting up the NucleoVac 24 Vacuum Manifold.

Figure 1. Setting up the NucleoVac 24 Vacuum Manifold. (1) Rubber closing plug. (2) Tubing connection. (3) Upper opening.

Processing columns via the NucleoVac 24 Vacuum Manifold

Figure 2. Processing columns with the NucleoVac 24 Vacuum Manifold. (4) NucleoSpin column. (5) Luer opening. (6) NucleoVac Mini Adapter. (7) NucleoVac Stopcock. (8) Luer plug.

NucleoVac 24 Vacuum Manifold procedure

Close the lower threaded opening of the NucleoVac 24 Vacuum Manifold (Figure 1) with the rubber closing plug (1). Screw in the tubing connection (2) in the upper opening (3) manually. Do not use a wrench as the conical screw thread might crack if the connection is over-tightened. Attach the vacuum tubing (not included).

For processing NucleoSpin (4) or NucleoSnap columns with the NucleoVac 24 Vacuum Manifold (Figure 2), insert NucleoSpin or NucleoSnap columns into the Luer openings (5; a). To avoid cross-contamination, we recommend using disposable NucleoVac Mini Adapters (6; b). For processing samples with different flow rates (e.g., large samle volumes), we recommend using NucleoVac Stopcocks (7; c) for maintaining constant vacuum pressure throughout the entire procedure. Close unused Luer openings with Luer plugs (8; d).

Overview

  • Time-saving processing of 24 samples in parallel
  • Parallel processing of silica columns (e.g., NucleoSpin and NucleoSnap columns) for nucleic acid purification
  • Fast processing of large sample volumes

More Information

Material Polypropylene
Number of samples 1–24
Waste capacity ≤900 ml
Column compatibility NucleoSpin columns, NucleoSnap columns


NucleoVac 24 and accessory product specifications

Product

Size

Specification

Cat. #

NucleoVac 24 Vacuum Manifold 1 each NucleoVac 24 Vacuum Manifold, 24 NucleoVac Mini Adapters, 24 Luer plugs, 2 tubing connections, 1 closing plug 740299
NucleoVac Mini Adapters 100 each Luer adapters for connecting NucleoSpin or NucleoSnap columns to NucleoVac 24 Vacuum Manifold 740297.100
NucleoVac Stopcocks

24 each

Stopcocks for handling different flow rates of NucleoSpin and NucleoSnap columns on a NucleoVac 24 Vacuum Manifold 740298.24

Applications

  • Nucleic acid purification by vacuum

Additional product information

Please see the product's Certificate of Analysis for information about storage conditions, product components, and technical specifications. Please see the Kit Components List to determine kit components. Certificates of Analysis and Kit Components Lists are located under the Documents tab.